{"id":3082,"date":"2023-11-28T16:50:08","date_gmt":"2023-11-28T16:50:08","guid":{"rendered":"https:\/\/cityandco.uk\/?page_id=3082"},"modified":"2023-12-01T13:27:27","modified_gmt":"2023-12-01T13:27:27","slug":"emergency-lighting-maintenance","status":"publish","type":"page","link":"https:\/\/cityandco.uk\/index.php\/maintenance-servicing\/emergency-lighting-maintenance\/","title":{"rendered":"Emergency Lighting Maintenance"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"3082\" class=\"elementor elementor-3082\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-adfcec1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"adfcec1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a1a2b28\" data-id=\"a1a2b28\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-51df6ab elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"51df6ab\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3984239\" data-id=\"3984239\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-65b9ca1 elementor-widget elementor-widget-spacer\" data-id=\"65b9ca1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-845be9b elementor-widget elementor-widget-spacer\" data-id=\"845be9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-367529a elementor-widget elementor-widget-heading\" data-id=\"367529a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Maintenance<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799e699 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"799e699\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Finally, to ensure that the system remains at full operational status, essential servicing should be specified. This would usually be performed as part of the testing routine, but in the case of consumable items such as replacement lamps, spares should be provided for immediate use.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6f19144 elementor-widget elementor-widget-spacer\" data-id=\"6f19144\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-4af334b\" data-id=\"4af334b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6633e28 elementor-widget elementor-widget-spacer\" data-id=\"6633e28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a69abf1 elementor-widget elementor-widget-image\" data-id=\"a69abf1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"751\" height=\"505\" src=\"https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-1024x689.jpg\" class=\"attachment-large size-large wp-image-3346\" alt=\"\" srcset=\"https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-1024x689.jpg 1024w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-300x202.jpg 300w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-768x517.jpg 768w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-327x220.jpg 327w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-387x260.jpg 387w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-1536x1034.jpg 1536w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-2048x1378.jpg 2048w, https:\/\/cityandco.uk\/wp-content\/uploads\/2023\/11\/electrician-is-installing-connecting-lamp-600x404.jpg 600w\" sizes=\"(max-width: 751px) 100vw, 751px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e491be4 elementor-widget elementor-widget-spacer\" data-id=\"e491be4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2b89654 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2b89654\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9199b21\" data-id=\"9199b21\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4a88d25 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4a88d25\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-c888bae\" data-id=\"c888bae\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4466bb8 elementor-widget elementor-widget-heading\" data-id=\"4466bb8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Servicing and testing<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47854da elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"47854da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>To test an emergency lighting system, a mains power failure on the normal lighting circuit \/ circuits or individual luminaries must be simulated. This will force the emergency lighting system to operate via the battery supply. This test can be carried out manually or automatically.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2542d4d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"2542d4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Manual testing<\/strong><\/p><p>A simulated mains failure can be achieved by providing a switch to isolate all lighting circuits \/ individual circuits \/ individual luminaires. If manual testing is utilised, the following points should be considered:<\/p><p>In a system with a single switch for the whole building or a large circuit, after simulating the mains failure it is necessary for the tester to walk the whole building or circuit, to check all emergency luminaire are operating correctly. After restoring the mains supply, the whole building or circuit must be walked again, to check that the emergency lights are recharging.<\/p><p>If the emergency luminaires are individually switched, only a single walk around the building will be needed. However, the test switches could spoil the decor of the building and they must be of a type that is tamper proof. After the tests, it is recommended that the performance of the system is logged in the fire safety logbook.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-adc5b75 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"adc5b75\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Automatic testing<\/strong><\/p><p>If the costs of an engineer\u2019s time and the disruption caused by manual testing are excessive, self-testing emergency lighting should be considered. Different formats are available to match particular site requirements. However, the results of the monthly and annual tests must still be recorded.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc7443 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"0bc7443\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>General information about emergency lighting testing<\/strong><\/p><p>BS EN 50172:2004 \/ BS 5266-8:2004 (Emergency escape lighting systems) specifies the minimum provision and testing of emergency lighting for different premises. Additional information on servicing can be found in BS 5266-1: 2011 (Code of practice for the emergency lighting of premises).<\/p><p>Discharge tests need to be undertaken outside normal working hours. In buildings that are permanently occupied, the test should be phased so only alternate luminaires are tested.<\/p><p>Regular servicing is essential. The occupier \/ owner of the premises shall appoint a competent person to supervise servicing of the system. This person shall be given sufficient authority to ensure the carrying out of any work necessary to maintain the system in correct operational mode.<\/p><p>Because of the possibility of a failure of the normal lighting supply occurring shortly after a period of testing of the emergency lighting system or during the subsequent recharge period, all full duration tests shall, wherever possible, be undertaken just before a time of low risk to allow for battery recharge. Alternatively, suitable temporary arrangements shall be made until the batteries have been recharged.<\/p><p>The following minimum inspections and tests shall be carried out at the intervals recommended below. The regulating authority may require specific tests.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-605c90e elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"605c90e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Daily emergency lighting inspection (only for central back-up systems)<\/strong><\/p><p>This check\u00a0<strong>only<\/strong>\u00a0applies to emergency lighting systems with a central back-up battery system. In this case, there is a daily visual inspection of indicators on the central power supply to identify that the system is operational. No test of operation is required. This test\u00a0<strong>does not<\/strong>\u00a0apply to emergency lighting with self-contained back-up batteries in each unit (standard emergency lighting).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b32052 elementor-widget elementor-widget-spacer\" data-id=\"6b32052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de4eb81 elementor-widget elementor-widget-heading\" data-id=\"de4eb81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Monthly emergency lighting tests<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4fce3df elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"4fce3df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>All emergency lighting systems must be tested monthly. The test is a short functional test in accordance with BS EN 50172:2004 \/ BS 5266-8:2004.<\/p><p>The period of simulated failure should be sufficient for the purpose of this test while minimising damage to the system components, e.g. lamps. During this period, all luminaires and signs shall be checked to ensure that they are present, clean and functioning correctly.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0be25d elementor-widget elementor-widget-heading\" data-id=\"b0be25d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Annual emergency lighting tests<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90acd10 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"90acd10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A test for the full rated duration of the emergency lights (e.g. 3 hours) must be carried out. The emergency lights must still be working at the end of this test.<\/p><p>The result must be recorded and, if failures are detected, these must be remedied as soon as possible.<\/p><p>It is common for fire alarm servicing companies to carry out the annual emergency light \u2018drain\u2019 test at the same time as they carry out fire alarm system maintenance, as this fills the waiting time of the \u2018drain\u2019 test with useful activity.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72a3f84 elementor-widget elementor-widget-heading\" data-id=\"72a3f84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">British and European Standards \u2013 Emergency Lighting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43f1eeb elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"43f1eeb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Emergency lighting is now covered by a series of interdependent standards that can be seen as forming a hierarchy as shown below.<\/p><p><strong>Base guidance document<\/strong><\/p><p>BS 5266-1: 2011 Code of practice for emergency lighting of premises. Gives general rules and guidance on the provision and operation of emergency lighting in most premises other than dwelling houses.<\/p><p><strong>System standards<\/strong><\/p><p>BS EN 1838:1999 \/ BS 5266-7:1999 Lighting applications \u2013 emergency lighting. Specifies the illumination to be provided by emergency lighting (including luminance, duration and colour).<\/p><p>BS EN 50172:2004 \/ BS 5266-8:2004 Emergency escape lighting systems. Specifies the minimum provision and testing of emergency lighting for different premises.<\/p><p><strong>Product standards<\/strong><\/p><p>BS EN 60598-1: 2008 Luminaires.\u00a0 General requirements and tests. See the 60598 series for particular requirements.<\/p><p>BS EN 62034:2006 Automatic test systems for battery powered emergency escape lighting. Specifies a test system for battery powered emergency lighting<\/p><p>BS EN 50171:2001 Central power supply systems. Specifies central power supply systems for emergency lighting luminaries.<\/p><p>Visit your local reference library or purchase copies of the requisite standards from BSI online; insert the BS number to see which titles are current. The links may not be inclusive but will give an indication of the guidance available.<\/p><p><strong>The Regulatory Reform (Fire Safety) Order 2005<\/strong><\/p><p>The HM Government entry level guides to the RRFSO for different types of non-domestic premises and the communal areas in HMOs each have a section entitled \u201cFurther guidance on emergency escape lighting\u201d, which provide additional relevant information. The guides can be accessed via this link:\u00a0Regulatory Reform (Fire Safety) Order guides.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57d7a01 elementor-widget elementor-widget-spacer\" data-id=\"57d7a01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0eab368 elementor-widget elementor-widget-spacer\" data-id=\"0eab368\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Maintenance Finally, to ensure that the system remains at full operational status, essential servicing should be specified. This would usually be performed as part of the testing routine, but in the case of consumable items such as replacement lamps, spares should be provided for immediate use. Servicing and testing To test an emergency lighting system,&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":3045,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-builder.php","meta":{"footnotes":""},"class_list":["post-3082","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/pages\/3082","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/comments?post=3082"}],"version-history":[{"count":19,"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/pages\/3082\/revisions"}],"predecessor-version":[{"id":3556,"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/pages\/3082\/revisions\/3556"}],"up":[{"embeddable":true,"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/pages\/3045"}],"wp:attachment":[{"href":"https:\/\/cityandco.uk\/index.php\/wp-json\/wp\/v2\/media?parent=3082"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}